THERMAL SHOCK CHAMBER SERIES

Our Air-to-Air Thermal Shock Chamber is specially designed for today's highly demanding environmental testing conditions where sample are tested through a series of extremes high and low temperature within a few seconds or minutes.

With our Air-to-Air Thermal Shock Chamber, chemical and physical changes or damage on the tested product can be easily detected. Our Air-to-Air Thermal Shock Chamber is designed with fully automated features and programs can be easily set on the touch screen LCD panel.

Features:

  • Smart Computer based programmable HONEYWELL control system with LCD display.
  • High resolution for control and automatic PID calculation.
  • State of art operation system with automatic pre-heating and pre-cooling function.
  • Automatic defrost function.
  • 2 zones chamber
  • Single zone chamber - introduces a new concept of thermal shock which can reduce the test space.

    The product is fixed in its position and the chamber is connected to hot and cold zones located at the top and bottom of the chamber.
  • Safety Protection

    System Over-Current Protection, Compressor Over-Load Protection, Compressor Over-Pressure Pro-tection, Thermal Protection, Electrical Fuse Protection & System Alarm Indication.

    SPECIFICATIONS
    Model
    2 zones chamber
    Single zone chamber

    TSD-40

    TSD-80

    TSS-150

    TSS-250

    Dimension (WxDxH)cm Internal

    40 x 35 x 30

    50 x 40 x 40

    60 x 50 x 50

    70 x 60 x 60

    External
    150 x 180 x 200
    160 x 180 x 220
    185 x 150 x 250
    190 x 170 x 270
    Temperature Range
    -70°C to 200°C
    Mechanism
    Basket moving between hot and cold zone
    Pneumatic door open alternative between hot and cold zone
    Driver
    Motor
    Pneumatic cylinder
    Temp. Recovery Time
    ≤ 5min
    Temperature Accuracy
    ± 0.5°C
    Heating Time
    From RT to 200°C within 30min
    Cooling Time
    +20°C to -70°C within 80 min and +20°C to -55°C within 65min
    Material
    Interior use SUS 304 and exterior use SUS 304 coated paint
    Control
    Honeywell LCD touch screen display controller
    Power Requirement
    380Vac or 415Vac ± 10%
    3 Phase 50 Hz (Standard)
    .
     